Controllers |
|
* Ensures
safe operation of system within pre-defined limits. |
*
Simple end-user interface. |
* Temperature
display of collector and top and bottom of cylinder, sensors
included. |
* Stagnation
indicator and system shut down. |
*
Legionella sterilization. |
* Fully
programmable for use with a direct or indirect secondary
heat sources. |
* Holiday
function and anti-freeze function. |
|
SOLCU1 |
* 3
inputs and 1 output. |
* For
use with a single array of up to 10 panels with one storage
tank. |
|
|
|
SOLCU2 |
*
5 inputs and 2 outputs. |
*
Allows more complicated set-ups than the SOLCU1 such as
east-west panels, swimming pool heat exchangers, dual
coil solar heating and solar heating of two DHW cylinders. |
|
SOLCU3 |
*
6 inputs and 3 outputs. |
Engineering
drawing of controller and pumpstation |
* Can be combined with a SOLFM15 or SOLFM25 flow meter
to display the heat generated in kW. The data is recorded
to an SD card which can then be imported to a spreadsheet
program such as Excel. |
|
|
Pump
station |
|
The
pump station transports the solar energy from the collector
to the domestic hot water cylinder by circulating Glycol
through insulated pipes. |
|
|
* Pre-assembled
for quick and easy installation |
* Compact
design makes good use of space and is fully insulated. |
* Variable
pump speed control for maximum efficiency. |
* Incorporates
a pressure relief valve, two non-return valves, flow meter
and two flush and fill connections for quick and easy
installation. |
* SOLPU1 – flow rates 1 to 20 l/min, 6m head. |
* SOLPU2 – flow rates 5 to 40 l/min, 7m head. |
|
|
Accessories |
|
The
Dimplex range of accessories has been specially designed
to cope with the higher temperatures and pressures that
can occur in a solar thermal system. |
|
|
Pre-insulated
flexible hose |
Making
connections in tight loft spaces is no longer a problem
with the flexible hoses. Available in 10 or 15m lengths
the flexible, stainless steel hoses come complete with
insulation, sensor cable and temperature resistant fixings
enabling quick installation. Fits directly on to pump
station and the 0.8m flexible hoses from the collector. |
|
|
Flush
and fill pump 240V |
|
Ideal
for installers who will be commissioning more than one
system. The pump makes it easy to flush the primary pipe
work of air and charge the system to the correct operating
pressure. The built-in filter combined with powerful pump
will remove any debris meaning that a water pre-flush
is not required. |
|
|
Air
separator |
If
you choose not to use the flush and fill pump, the air
separator will remove air from the Glycol during commissioning
making installation quicker. |
|
Feed
though tile |
For
on-roof installations the feed through tile allows access
through the roof for the pipe work whilst maintaining
the integrity of the roof. |
|
Heat
transfer medium test kit |
Ideal
for the annual maintenance check, this test kit provides
everything required to check the frost protection and
pH of the Glycol. |
|
|
Thermostatic
mixing valve |
|
22mm
thermostatic mixing valve for use with DHW and the SCx
solar cylinders. |
|
|
Flow
meter |
For
direct connection to the SOLCU2 or SOLCU3 in order to
give an accurate measurement of the energy captured.SOLFM120
from 1 to 20l/min and SOLFM240 from 2 to 40l/min. |
|
| |